Shimpo DEG-2000 User Manual

Browse online or download User Manual for Tools Shimpo DEG-2000. SHIMPO DEG-2000 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Digital Electric Micrometer

NO. ELE-DE011101 DEG2000 Instruction ManualDigital Electric Micrometer

Page 2 - Contents

8Rear of standard model DEG2000-NAC85~264VEXT I/OANALOG SW.ETC RS232CABCDRear of dedicated model DEG2000-A for air micrometerCD◯19 Electric micrometer

Page 3 - 3. Main Modes

95. SpecificationsItem Specification RemarksPower supply voltage andfrequency85 to 264 VAC, 50/60 Hz 100 VAC power cable supplied asaccessoryPower sup

Page 4 - Item and judgment LEDs

10Item Specification RemarksJudgment method ±NG and rank Set for each item.1. EQUAL Equal ranking:Maximum of 99 ranks(Judgment result output:Maximum o

Page 5 - Main display

116. Operation6.1 DescriptionHere is described a series of steps from connecting a measuring head to measuring withthe head.Connect the measuring head

Page 6 - OK OK +OK +NG

126.2 MeasuringMeasure mode• The conditions indicated by the colors of the item and judgment LEDs in this mode areas shown in Table 4.Table 4. Conditi

Page 7

136.3 Automatic masteringNotes: 1. This instrument is a comparative measuring instrument. Be sure to use itafter calibrating it with a master.2. Du

Page 8 - ENT (enter) key

146.4 SettingThe set value is entered and changed in the set mode.6.4.1 Set modeThe set mode covers the following settings:[XDUCER]The sensitivity of

Page 9

15[RANK]The OK ranking method of each item and the number of OK ranks are set.[LIMIT]The OK rank boundary of each item is set.Refer to “Set mode (5)”

Page 10

167. I/O Description7.1 Serial output(1) DescriptionThis instrument can output the measured values to a printer and communicate with apersonal compute

Page 11 - 5. Specifications

17(7) Data request command from PC➀ Measured value latch (data hold) commandTransmit the command byte “E”<45H>. The instrument holds the meas

Page 12 - Item Specification Remarks

Contents1. Introduction ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 12. Main Features ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 13. Main Modes・・・・・

Page 13 - 6. Operation

187. 2 External input(1) DescriptionThe instrument allows no-voltage contacts, such as those of an external button or footswitch, to be connected to t

Page 14 - 6.2 Measuring

197.3 Judgment result outputThe result of three-item judgment, two-item judgment, or ranking is output to the DCinput/output connector. (refer to ◯15

Page 15 - 6.3 Automatic mastering

207.3.2 Input signal arrangementNote: The input signals are enabled when “READY” is turned on. The followingtable shows the input signal arrangemen

Page 16 - 6.4 Setting

217.3.3 Procedure for calibrating instrument with masters by external input(1) DescriptionSet the minimum and maximum masters in that order.(2) Master

Page 17

227.3.4 Measuring procedure(1) DescriptionIn the measure mode, the instrument continues to produce the judgment result output.In the case of static me

Page 18 - 7.1 Serial output

237.3.5 Selecting judgment result output and BCD outputNumber 1 2 3 4 5 6Parallel Parallel Parallel Parallel CodeOutput typeOK 3 orlessOK 7 orlessOK 1

Page 19

247.3.6 Three-item judgment result output –– Output signal arrangementThe three-item judgment result output signal is output when “ALL ITEM” is select

Page 20 - 7. 2 External input

257.3.7 Two-item judgment result output –– Output signal arrangementThe two-item judgment result output signal is output when “ITEM 1&2” is select

Page 21 - 7.3 Judgment result output

267.3.8 Ranking output (OK rank 16 or less) –– Output signal arrangementThe ranking output signal is output when “ITEM 1”, “ITEM 2” or “ITEM 3” is sel

Page 22

277.3.9 Ranking output (OK rank 39 or less) –– Output signal arrangement (option)The ranking output signal is output when “ITEM 1”, “ITEM 2” or “ITEM

Page 23 - (2) Mastering

11. IntroductionThe digital electric micrometer is a measuring instrument with a large easy-to-see(three-color) digital display and an automatic maste

Page 24 - 7.3.4 Measuring procedure

287.3.10 Ranking code output (OK rank 99 or less) –– Output signal arrangementThe ranking code output signal is output when “ITEM 1”, “ITEM 2” or “ITE

Page 25

297.3.11 BCD output –– Input/output signal arrangement (option)The BCD input/output signal is output when “ITEM 1”, “ITEM 2” or “ITEM 3” is selectedwi

Page 26

307.3.12 Timing chartsThree-item judgment and two-item judgment (I: Input signal to instrument, O: Outputsignal from instrument)Ranking (I: Input sign

Page 27

317.3.13 Connector pin arrangement diagramA cable connector (57-30360 and DDK make) is supplied as accessory. Usually, acable is not supplied as ac

Page 28

327.3.14 Input circuit diagramPC8444.7kDC12~24V1098~17.3.15 Output circuit diagramOpen collector output: Maximum of 50 mA per output signal~17273536LP

Page 29

338. Model Identification DEG 20 00 –– N –– DP9. Options9.1 Instrument➀ Digimatic output: Output to DP-1 printer (cable supplied as acc

Page 30

3411. TroubleshootingPhenomenon Cause RemedyRepeatability is not stable.➀ Measuring head is looselysecured.➀ Retighten its fasteners.➀ Specified power

Page 31 - Decimal place

3513. Operation Flow

Page 34 - MAX 50mA

24. Names and Functions of Controls and Parts-NG-OKOK +OK +NG123◯1 Item and judgment LEDsIndicate the judgment result and measurement under way (as sh

Page 42

4514. Work SheetDEG2000 Work Sheet No. 1Manufacture No.:ProgramSetting descriptionPROG 1 PROG 2 PROG 3 PROG 4Input module MODULEIndicating range I-RAN

Page 43

46ProgramSetting descriptionPROG 1 PROG 2 PROG 3 PROG 4ITEM ITEM 2 STRUCT MAS 1MAS 2Item constitutive data(Sign and coefficientinput)ITEM 1Measuring f

Page 44

47DEG2000 Work Sheet No. 2Manufacture No.PROG 1 PROG 2 PROG 3 PROG 4Program item Setting descriptionITEM1ITEM2ITEM3ITEM1ITEM2ITEM3ITEM1ITEM2ITEM3ITEM1

Page 45

3-NG-OKOK +OK +NG123◯2 Main displayShows a value or condition in one of three colors. The display colors in each mode areas given in Table 2.Table

Page 46

48PROG 1 PROG 2 PROG 3 PROG 4Program item Setting descriptionITEM1ITEM2ITEM3ITEM1ITEM2ITEM3ITEM1ITEM2ITEM3ITEM1ITEM2ITEM3A/D external input EXT CHJudg

Page 47 - DEG2000 Work Sheet No. 1

HEAD OFFICE 2-215 SOBU-DAI ZAMA CITY, KANAGAWA PREF. 228-8570 JAPANURL http://home.tosok.co.jp/MEASURING MACHINERY SALES DEPT.OVERSEAS SALES GROUPTEL

Page 48

4-NG-OK OK +OK +NGENTRSTPROGSET MASSET MAS◯3 Display item judgment LEDsJudge the data shown on the main display. OK is indicated by green, ±OK by o

Page 49 - DEG2000 Work Sheet No. 2

5-NG-OK OK +OK +NGENTRSTPROGSET MASSET MAS◯6 Left arrow /SET keyMode Keying OperationMeasure Press 2 sec. Mode is changed to set mode.Set Press once.

Page 50

6-NG-OK OK +OK +NGENTRSTPROGSET MASSET MAS◯10 RST (reset) keyMode Keying OperationHold measuredvaluePress once. Measured value hold is cleared.Set Pre

Page 51

7◯12 RS232C connectorA serial communication connector for connecting a personal computer or printer.◯13 Switch input connectorA connector for entering

Comments to this Manuals

No comments